Optical Disc Drive Compatibility: GD-ROM

From Redump Wiki

(Difference between revisions)
Jump to: navigation, search
(See Also)
 
(24 intermediate revisions not shown)
Line 4: Line 4:
==LD Area==
==LD Area==
-
For dumping the '''LD Area''', the same rules apply as in dumping a CD as they use the same technology. The list of compatible drives for dumping LD Area is [[Optical Disc Drive Compatibility: CD|here]].
+
For dumping the '''LD Area''', the same methodology applies for dumping a CD-ROM. The list of compatible drives for dumping LD Area is [[Optical Disc Drive Compatibility: CD|here]].
==HD Area==
==HD Area==
-
The '''HD Area''' dumping the process is different, use one of the recommended drives below:
+
All firmware downloads listed are swapless.
-
*HD Area: GD-ROM (Pressed) - (install [[Optical_Disc_Drive_Firmware#Kreon|Kreon firmware]]):
+
{| class="wikitable sortable"
-
**Samsung TSSTCorp models:
+
! Manufacturer || Model || Firmware Download || Notes
-
***TS-H353A aka SH-D163A
+
|-
-
***TS-H352C aka SH-D162C
+
| Lite-On || LH-16D1P || [https://archive.org/download/lh-16-d-1-p-swapless.-7z/LH-16D1P-Swapless.7z] ||
-
***TS-H192C
+
|-
-
*HD Area: GD-R (Burned Preproduction) - Working to some at least extent (WARNING: needs significant additional testing):
+
| Lite-On || DH-16D1S || [https://archive.org/download/lite-on-dh-16d1s-swapless-firmware/ZZ00.bin] ||
-
**Plextor: PX-708A, PX-755A, PX-755SA, PX-4012TA[http://forum.redump.org/topic/48401/gdr-dumping-for-redump-research-discussion/]
+
|-
-
**For additional research on compatibility, see [[Optical Disc Drive Compatibility for GD-ROM and GD-R Dumping]].
+
| Samsung TSSTCorp || SH-C522C || [https://archive.org/download/kreon-firmware/TS-H192C-Swapless.7z] ||
 +
|-
 +
| Samsung TSSTCorp || SH-D163A || [https://archive.org/download/kreon-firmware/SH-D163A_DC02_KREON_V100.bin] || Old firmware swap-disc firmware [https://archive.org/download/kreon-firmware/SH-D163A_SB01_KREON_V100/ here].
 +
|-
 +
| Samsung TSSTCorp || SH-D162C || [https://archive.org/download/kreon-firmware/SH-D162C_DC02_KREON_V100.bin] || Old firmware swap-disc firmware [https://archive.org/download/kreon-firmware/SH-D162C_TS05_KREON_V100/ here].
 +
|-
 +
| Toshiba || TS-H192C || [https://archive.org/download/kreon-firmware/TS-H192C-Swapless.7z] || Rebadged SH-C522C.
 +
|-
 +
| Toshiba || TS-H353A || [https://archive.org/download/kreon-firmware/SH-D163A_DC02_KREON_V100.bin] || Rebadged SH-D163A. Old firmware swap-disc firmware [https://archive.org/download/kreon-firmware/SH-D163A_SB01_KREON_V100/ here].
 +
|-
 +
| Toshiba || TS-H352C || [https://archive.org/download/kreon-firmware/SH-D162C_DC02_KREON_V100.bin] || Rebadged SH-D162C. Old firmware swap-disc firmware [https://archive.org/download/kreon-firmware/SH-D162C_TS05_KREON_V100/ here].
 +
|}
 +
 
 +
===Firmware Installation Instructions: Samsung & Toshiba===
 +
* Download the appropriate firmware for your model.
 +
* Download the app [https://archive.org/download/kreon-firmware/sfdnwin.exe sfdnwin.exe] and place it in the same folder as the firmware download.
 +
* Open the Command Prompt app and '''cd''' (change directory) to the location of the files.
 +
* Run the command: '''sfdnwin.exe -nocheck'''
 +
* You'll get a pop up that says "-Nocheck Use!!!", click "OK" beneath it. This will open the SFDNWIN app.
 +
* In the app, select your "Drive".
 +
* Click the light-blue Folder icon in the upper left part of the app, then select the ".bin" firmware file.
 +
* Click the green Folder icon.
 +
* If the firmware was successfully flashed, you will be asked to restart your computer, do this.
 +
 
 +
'''Notes''':
 +
*When connected with a USB adapter, SATA models may falsely claim the firmware was not updated. More research is helpful, please report your findings [http://forum.redump.org/post/120066/#p120066 here].
 +
*'''Linux''' will produce bad dumps if using the libata driver on some SATA chipsets due to silently erroring on the lock state command. Some DiscImageCreator builds will not report the dump as bad, so it is recommended to use redumper for Kreon dumps on Linux.
 +
 
 +
===Firmware Installation Instructions: Lite-On===
 +
* Download the Lite-On [https://archive.org/download/lite-on-optical-disc-drive-flash-utility/Flash_Utility.exe Flash Utility].
==See Also==
==See Also==
 +
*[[GD-ROM Dumping Guide]]
 +
*[[GD-R Dumping Guide]]
 +
*[[GD-R SD Card Dumping Guide]]
*[[Optical Disc Drive Compatibility]]
*[[Optical Disc Drive Compatibility]]
*[[Optical Disc Drive Compatibility Testing for GD-ROM and GD-R Dumping]]
*[[Optical Disc Drive Compatibility Testing for GD-ROM and GD-R Dumping]]
[[Category:Optical Disc Drives]]
[[Category:Optical Disc Drives]]

Latest revision as of 03:47, 19 February 2026

A list of optical disc drives compatible with dumping GD-ROM discs.

GDs contain two distinctly different "Areas" of data ("LD Area" and "HD Area"), separated by a ring. Both Areas are dumped with a separate process.

Contents

LD Area

For dumping the LD Area, the same methodology applies for dumping a CD-ROM. The list of compatible drives for dumping LD Area is here.

HD Area

All firmware downloads listed are swapless.

Manufacturer Model Firmware Download Notes
Lite-On LH-16D1P [1]
Lite-On DH-16D1S [2]
Samsung TSSTCorp SH-C522C [3]
Samsung TSSTCorp SH-D163A [4] Old firmware swap-disc firmware here.
Samsung TSSTCorp SH-D162C [5] Old firmware swap-disc firmware here.
Toshiba TS-H192C [6] Rebadged SH-C522C.
Toshiba TS-H353A [7] Rebadged SH-D163A. Old firmware swap-disc firmware here.
Toshiba TS-H352C [8] Rebadged SH-D162C. Old firmware swap-disc firmware here.

Firmware Installation Instructions: Samsung & Toshiba

  • Download the appropriate firmware for your model.
  • Download the app sfdnwin.exe and place it in the same folder as the firmware download.
  • Open the Command Prompt app and cd (change directory) to the location of the files.
  • Run the command: sfdnwin.exe -nocheck
  • You'll get a pop up that says "-Nocheck Use!!!", click "OK" beneath it. This will open the SFDNWIN app.
  • In the app, select your "Drive".
  • Click the light-blue Folder icon in the upper left part of the app, then select the ".bin" firmware file.
  • Click the green Folder icon.
  • If the firmware was successfully flashed, you will be asked to restart your computer, do this.

Notes:

  • When connected with a USB adapter, SATA models may falsely claim the firmware was not updated. More research is helpful, please report your findings here.
  • Linux will produce bad dumps if using the libata driver on some SATA chipsets due to silently erroring on the lock state command. Some DiscImageCreator builds will not report the dump as bad, so it is recommended to use redumper for Kreon dumps on Linux.

Firmware Installation Instructions: Lite-On

See Also

Personal tools